Catalogue No. LII – TB - 12

24 Service Pumps

Manufacturer: SEDICAL

Mechanical design: single

Mechanical seal material: C / SiC

Year of manufacture:  2006

 

Total working hours: < 1,000 hrs. 

Performed maintenance work: N. A. 

EC Declaration: CE marking plates attached

Available Documentation for all items:

- SEDICAL pumps start up, operation and maintenance manual

- ABB drive motor user manual

- TT - FLYGT Hydrovar PD 39 S frequency converter operating instructions

- Pump technical data sheet

- Pump pressure - throughput curve

Catalogue No. LII – TB – 12A

IAP01-BRD+15 / 1

Dedicated use: Cooling circuit

Model: SDM 65 / 190.1-0.75 / K

Throughput: 10 cbm / h

Pressure: 10 mWc

Impeller: 174 mm

Catalogue No. LII – TB – 12B

IAP01-BRD+15 / 2

Dedicated use: Cooling circuit

Model: SDM 65 / 190.1-0.75 / K

Throughput: 10 cbm / h

Pressure: 10 mWc

Impeller: 174 mm


Catalogue No. LII – TB – 12C

IAP02-BST-10 / 1

Dedicated use: Secondary ciruit Chiller -10 °C

Model: SIM 80 / 270.1-4.0 / K

Throughput: 52,2 cbm / h

Pressure: 14 mWc

Impeller: 42 mm


Catalogue No. LII – TB – 12D

IAP02-BST-10 / 2

Dedicated use: Secondary ciruit Chiller -10 °C

Model: SIM 80 / 270.1-4.0 / K

Throughput: 52.2 cbm / h

Pressure: 14 mWc

Impeller: 242 mm


Catalogue No. LII – TB – 12E

IAP02-BPE-10 / 1

Dedicated use: Sole ciruit Chiller -10 °C

Model: SIM 80 / 270.1-5.5 / K

Throughput: 48.9 cbm / h

Pressure: 18.5 mWc

Impeller:  270 mm


Catalogue No. LII – TB – 12F

IAP02-BPE-10 / 2

Dedicated use: Sole ciruit Chiller -10 °C

Model: SIM 80 / 270.1-5.5 / K

Throughput: 48.9 cbm / h

Pressure: 18,5 mWc

Impeller: 270 mm


Catalogue No. LII – TB – 12G

IAP02-BST-40 / 1

Dedicated use: Secundary ciruit Chiller -40 °C

Model:  SDM 100 / 290-7.5 / K

Throughput: 77.4 cbm / h

Pressure: 16 mWc

Impeller: 269 mm


Catalogue No. LII – TB – 12H

IAP02-BST-40 / 2

Dedicated use: Sole ciruit Chiller -40 °C

Model: SDM 100 / 290-7.5 / K

Throughput: 77.4 cbm / h

Pressure: 16 mWc

Impeller: 269 mm

Catalogue No. LII – TB – 12I

IAP04-BSCP/ 1

Dedicated use: Hot water production

Model: SIM 50 / 265.1-1.5 / K

Throughput: 17.3 cbm / h

Pressure: 15 mWc

Impeller: 221 mm.


Catalogue No. LII – TB – 12J

IAP04-BSCP / 2

Dedicated use: Hot water production

Model: SIM 50 / 265.1-1.5 / K

Throughput: 17.3 cbm / h

Pressure: 15 mWc

Impeller: 221 mm.


Catalogue No. LII – TB – 12K

TUB01-BSC / E / 1

Dedicated use: Hot water production

Model: SDM 80 / 270.1-1.5 / K

Throughput: 12 cbm / h

Pressure: 15 mWc

Impeller: 214 mm


Catalogue No. LII – TB – 12L

TUB01-BSC / E / 2

Dedicated use: Hot water production

Model: SDM 80 / 270.1-1.5 / K

Throughput: 12 cbm / h

Pressure:15 mWc

Impeller: 214 mm


Catalogue No.
LII – TB – 12Q

IC01-BST+7 / 1

Dedicated use: Water supply

Model:  SDM 80 / 270.1-2.2 / K

Throughput: 36 m 3 / h

Pressure: 12 mWc

Impeller: 212 mm


Catalogue No. LII – TB – 12R

IC01-BST+7 / 2

Dedicated use: Water supply

Model:  SDM 80 / 270.1-2.2 / K

Throughput: 36 cbm / h

Pressure: 12 mWc

Impeller: 212 mm


Catalogue No. LII – TB – 12S

IC01-BPE+7 / 1

Dedicated use: Water supply

Model:  SIM 80 / 270.1-4.0 / K

Throughput: 39.6 cbm / h

Pressure: 16 mWc

Impeller: 239 mm


Catalogue No. LII – TB – 12T

IC01-BPE+7 / 2

Dedicated use: Water supply

Model: SIM 80 / 270.1-4.0 / K

Throughput: 39.6 cbm / h

Pressure: 16 mWc

Impeller: 239 mm


Catalogue No. LII – TB – 12U

IC02-BSCC / 1

Dedicated use: Warm water for air conditioning

Model:  SDM 100 / 290-3.0 / K

Throughput: 27 cbm / h

Pressure: 16 mWc

Impeller: 230 mm


Catalogue No. LII – TB – 12V

IC02-BSCC / 2

Dedicated use: Warm water for air conditioning

Model: SDM 100 / 290-3.0 / K

Throughput: 27 cbm / h

Pressure: 16 mWc

Impeller: 230 mm


Catalogue No. LII – TB – 12W

IC02-BSCS / 1

Dedicated use: Warm water

Model: SDM 65 / 190.1-0.37 / K

Throughput: 7.2 cbm / h

Pressure: 8,0 mWc

Impeller: 157 mm


Catalogue No. LII – TB – 12X

IC02-BSCS / 2

Dedicated use: Warm water

Model:  SDM 65 / 190.1-0.37 / K

Throughput: 7.2 cbm / h

Pressure: 8,0 mWc

Impeller: 157 mm


Catalogue No. LII – TB – 12Y

IC02-BPCR / 1

Dedicated use: Warm water

Model:  SDM 100 / 290-4.0 / K

Throughput: 50.4 cbm / h

Pressure: 18 mWc

Impeller: 256 mm


Catalogue No. LII – TB – 12Z

IC02-BPCR / 2

Dedicated use: Warm water

Model:  SDM 100 / 290-4.0 / K

Throughput: 50.4 cbm / h

Pressure: 18 mWc

Impeller: 256 mm


Catalogue No. LII – TB – 12AA

BS_EDAR-01

Dedicated use: Unknown

Model: SDM 65 / 190.1-0.75 / K

Throughput: 10 cbm / 4

Pressure: 11 mWc

Impeller: 183 mm


Catalogue No. LII – TB – 12AB

BS_EDAR-02

Dedicated use: Unknown

Model:  SDM 65 / 190.1-0.75 / K

Throughput:10 cbm / 4

Pressure: 11 mWc

Impeller: 183 mm


 


General Features